The runbook span table, the phase-4 task list and the data reference all
conflicted: this branch had already expanded them with the open-phase,
avalanche and proposal-prefix attributes. Keep this branch's tables and
apply the close-time rename to their rows.
The close_time entry in ledger_history_mismatch_total{reason} is a metric
label value, not the span attribute, and is deliberately unchanged.
The consensus and ledger attribute tables conflicted: this branch had
already rewritten both, adding the open-phase and avalanche attributes and
correcting tx_count/tx_failed to sit on tx.apply alone. Keep this branch's
tables and apply the close-time rename to their rows, rather than taking
either side whole.
Update the consensus and ledger key inventories and the spanmetrics
dimension comment in both collector configs, so they name the emitted
keys. The comment's last_close_time reference is a server_info gauge, not
the span attribute, and is left as it is.
The emitted keys carry the unit and epoch suffix. Update the consensus
and ledger attribute tables and the ledger.build span row to match.
The Close Time Drift panel row is left alone: phase-7 removes that whole
table, so editing it here would only conflict on the way forward.
The consensus.accept.apply row listed close_time, parent_close_time and
close_time_self. The emitted keys carry the unit and epoch suffix, so
update the row to match.
The emitted keys are close_time_ripple_epoch_s,
parent_close_time_ripple_epoch_s and close_time_self_ripple_epoch_s.
Update the consensus.accept.apply attribute tables and the close-time
attribute descriptions to match.
The emitted key is close_time_ripple_epoch_s, which names its unit and
epoch. Update the ledger attribute table to match.
ledger_index and ledger_tx_count in the same table belong to a separate
rename and are left as they are.
Nine files conflicted. Resolutions, and why:
Telemetry.cpp - upstream carried its own initMetrics(), makeResource() and
makeMetricExporter(); this branch already has an initMetrics() that builds the
exporter inline and uses makeMetricsResource(), which stamps xrpl.node.id only
when it is already known. Keeping both would have defined initMetrics() twice.
Kept this branch's, then pointed its reader at setup_.metricExportInterval and
setup_.metricExportTimeout: upstream turned those constants into [telemetry]
keys and removed the old ones, so the previous spelling no longer resolves.
OTelCollector.h - kept upstream's parameter docs. This branch's text promised
instanceId, serviceName and networkType become resource attributes; the
constructor marks all three [[maybe_unused]] and the .cpp already says they are
not read.
CollectorManager.cpp - kept upstream's comment for the same reason.
node-health.json - kept this branch's 60 panels. Upstream's only change to the
file was job_count to jobq_job_count, which this branch already had.
cfg/xrpld-example.cfg - composed. Kept this branch's warning that
service_instance_id must be set explicitly for the metrics pipeline, took
upstream's traces_endpoint rename, and removed a duplicate metrics_endpoint
entry along with the claim that metrics derive from the traces URL by rewriting
the signal path. Nothing derives it; both metric exporters read
metrics_endpoint. 17 keys, one entry each.
05-configuration-reference.md - both sides misdescribed the parser. Kept this
branch's fuller text, corrected the endpoint default to traces_endpoint, and
replaced the "resolve their URL differently" table with what the code does now.
09-data-collection-reference.md, 06-implementation-phases.md,
Phase7_taskList.md - kept this branch's versions, which drop a metric that was
never implemented, correct the state encoding to 0-6, and rename nudb_bytes to
stored_object_bytes. Re-applied upstream's rpc_requests_total fix, which taking
this side had reverted.
phase-6 corrected the Consensus Health template-variable table to name
service_instance_id, the label that dashboard actually filters on. This branch
removes that table entirely - the section is restructured around a
Prometheus-label reference and a pointer to the runbook - so the corrected row
has nothing to land in. Resolved by keeping the restructured section; phase-6's
fix remains correct for phase-6, where the table still exists.
The [telemetry] cfg block merged without conflict: the composed 14-key block
from upstream and this branch's metrics_endpoint, metric_export_interval_ms and
metric_export_timeout_ms entries coexist, 17 keys with one entry each.
Both sides documented the same six [telemetry] keys, so the automatic merge
duplicated all of them. Resolved by keeping this branch's structure - which
already covers all 14 keys and groups them under TLS and batch-processor
headings - and folding in the corrections from the upstream side:
- endpoint is renamed to traces_endpoint, which is what the parser reads, and
described as used verbatim including its signal path.
- use_tls no longer claims to enable TLS. The exporter's URL scheme selects
TLS; this key only decides whether tls_ca_cert reaches it as a CA bundle.
- tls_ca_cert records that the path is not opened while the config is parsed,
so an unreadable file shows up as an export failure rather than at startup.
- service_instance_id explains that it is normally left unset and filled in
from the node public key during startup.
Section::value_or in 05-configuration-reference.md becomes Section::valueOr;
that member does not exist under the other spelling.
The native-metrics pipeline built its own OTLP/HTTP exporter and set only the
URL, so an operator who enabled TLS got mutual TLS on the trace exporter and a
plaintext-configured exporter for metrics. cfg/xrpld-example.cfg promises TLS for
"the OTLP exporter connection" with no carve-out, and two exporters exist. The
exporter now reads the same four [telemetry] TLS keys the trace exporter does.
Its resource was also thinner than the trace resource: service.name was
hardcoded, and service.version, xrpl.network.id and xrpl.network.type were
absent. Because the collector promotes resource attributes to labels, an operator
setting service_name split their fleet - spans carried the configured name while
every XRPL_METRIC_ series still said xrpld, blanking native-metric panels in
every dashboard that filters on it. All four now come from config, and
xrpl.network.type is derived inside from network_id through the shared
networkTypeFromId so a caller cannot supply a mismatched pair.
start() and initExporterAndProvider() take a StartOptions aggregate rather than
growing to eleven positional parameters, seven of them same-typed strings where a
swap would compile silently and stamp the wrong label - the defect class this
change exists to remove. It is constructed at one production site, so replacing
it with Telemetry::Setup once that is exposed stays a single-site edit.
service.version, service.instance.id and xrpl.node.id are stamped only when
non-empty, keeping this pipeline's existing behaviour of omitting an attribute
rather than writing it blank.
Also corrects three plan-doc references that cited line numbers rather than
symbols; the reader line moved and the numbers differ per branch.
Addresses review findings on the native-metrics work.
StatsDCollector::onTimer drained the send buffer inside the polling_ gate. That
gate holds back hook handlers until the application's services are built, but
sendBuffers() is socket I/O. StatsDEventImpl derives only from EventImpl, so it
never enters metrics_ and posts straight to the buffer; its |ms timings piled up
before onCollectionReady and were dropped after onCollectionStopping. The drain
now runs every tick, and outside metricsLock_, so onCollectionStopping no longer
waits on a UDP flush.
TelemetryImpl's constructor left meterProvider_ set when initMetrics() threw.
initMetrics publishes globally as its last step, so a throw left getMeter()
callers holding a provider nothing else could reach. Reset it in the catch.
~ApplicationImp caught only std::exception around telemetry shutdown while the
callees reach third-party SDK code, so a foreign exception would have terminated
the process. Added a logging catch-all.
ValidationTracker's hard trim evicted by unordered_map bucket order. It now
evicts oldest-first, so the entry dropped under pressure is the one least likely
to still reconcile.
The GetMeter test restored the global meter provider only on the success path,
and ASSERT_TRUE early-returns past it. Uses xrpl::ScopeExit instead.
The hook debounce window is a named constant rather than a bare 500 in a
comparison, and the metric export cadence becomes operator-configurable through
metric_export_interval_ms and metric_export_timeout_ms. Both are range-checked:
the SDK warns and silently substitutes its own 60s/30s defaults when the timeout
is not below the interval, so an unchecked value would slow export rather than
speed it up. Parsing uses a signed representation because lexical_cast<uint32_t>
accepts a leading minus and wraps it.
Naming corrections: CollectorManager documented exported_instance, which no OTel
dashboard uses; node-health queried job_count where the exported name is
jobq_job_count; network-traffic and overlay-traffic-detail referenced an
undeclared DS_PROMETHEUS variable; the counter table omitted the _total suffix
the Prometheus exporter appends; the plan docs and task list carried an xrpld_
prefix formatName never applies; and OTelCollector::New()'s contract promised its
instanceId, serviceName and networkType arguments were read, contradicting the
definition that marks them unused.
The Consensus Health template-variable table documented $node as resolving via
exported_instance. That dashboard defines $node as
label_values(target_info, service_instance_id) and its panels filter on
service_instance_id; exported_instance appears in it zero times.
exported_instance is a real label, but it belongs to the StatsD boards shipped
alongside, where Prometheus renames a scraped instance label that collides with
the target's own. Documenting it against an OTel dashboard pointed readers at
the wrong pipeline's label.
The commented [telemetry] block in cfg/xrpld-example.cfg documented 8 of the 14
keys the parser accepts. Add the six that were missing - service_instance_id,
use_tls, tls_ca_cert, batch_size, batch_delay_ms and max_queue_size - each with
the unit and default read from the parser, and rename the documented endpoint
key to traces_endpoint so it matches what makeTelemetrySetup reads.
use_tls is documented for what it does rather than what its name suggests: it
gates whether tls_ca_cert reaches the exporter as a CA bundle, while the scheme
of traces_endpoint is what selects TLS. The path is not opened during parsing,
so an unreadable file surfaces as an export failure at runtime.
05-configuration-reference.md named three symbols that do not exist:
setup_Telemetry, make_Telemetry and Section::value_or. Correct them to
makeTelemetrySetup, makeTelemetry and Section::valueOr.
clang-tidy reported six bugprone-unchecked-optional-access errors: the dataflow
analysis does not treat ASSERT_TRUE(x.has_value()) as establishing the
precondition, because the assertion's early return is hidden inside a macro. Three
sites now guard with a plain if + FAIL(), the form already used elsewhere in this
file and one the analysis does model.
The fourth site compares the whole optional instead. That covers both "was it
parsed" and "are the bounds right" in one exact assertion, and because it is
EXPECT rather than ASSERT every row of the table is now checked -- previously one
bad row returned from the test and hid the other five.
parseLedgerRange uses std::errc, which comes from <system_error>; the header
included only <charconv>, which misc-include-cleaner flagged.
kMetricExportInterval and kMetricExportTimeout were declared but the reader
options set the same values as literals, so both constants were unused. constexpr
at namespace scope has internal linkage, so clang reports them under
-Wunused-const-variable, which -Dwerr=ON makes fatal: it failed the compile on
ubuntu-clang-release-amd64 and macos-arm64-release, and clang-tidy as well.
Using them removes two magic numbers and keeps the comment that explains why the
interval is 1 s.
Two conflicts, both additions at the same spot:
NetworkOPs.cpp include block kept develop's rpc/detail/SyntheticFields.h
alongside this branch's telemetry/MetricsRegistry.h; .cspell.config.yaml
kept both new words.
NetworkOPs.cpp include block: develop replaced DeliveredAmount.h,
MPTokenIssuanceID.h and NFTSyntheticSerializer.h with the single
rpc/detail/SyntheticFields.h. Kept that and this branch's two telemetry
includes.
Two different facts were sharing one attribute key. The sync-diagnostics
branch already emits validation_status on consensus.validation.accept,
carrying what the validation store did (ValStatus: current, stale,
bad_seq, multiple, conflicting, unknown) with a mapping function and
tests behind it. This branch then added validation_status on
consensus.validation.receive for which exit the receive path took
(queued, dropped_diverged, dropped_load).
One key with two value domains means any aggregation that does not also
filter on span name mixes them. Merging the two branches also produced a
duplicate constexpr declaration in one header, which is how the compiler
surfaced it.
The established accept-path key keeps its name; this one becomes
validation_receive_status, qualified by the span phase it describes. The
values are unchanged.
phase-4 renamed the shared close_time attribute to
close_time_ripple_epoch_s, naming its unit and epoch. Two consumers here
still referenced the old spelling and broke the build once the rename
merged forward: the re-export in LedgerSpanNames.h and the setAttribute
call in BuildLedger.cpp.
Both are phase-6 content, so they are fixed here rather than upstream.